详细阐述德国DIN EN ISO11997-1循环腐蚀测试标准的试验方法和步骤

日期:08-07  点击:  属于:标准释疑
DIN EN ISO11997-1循环腐蚀测试标准是德国标准化协会发布的色漆和清漆.耐周期性腐蚀条件的测定.第1部分:湿(盐雾)/干/潮湿(ISO 11997-1-2005),下文摘录讲解其核心试验方法和步骤

德国DIN EN ISO11997-1循环腐蚀测试标准及复合盐雾测试方法

Cycle A

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,将氯化钠溶解在水中,使溶液的浓度为(50±10g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle设置盐雾箱执行以下循环
Step Time h Temp Condition Notes
1 2 35±2 Salt spray  
2 4 60±2 Dry:20-30%  
3 2 50±2 Wet:95%RH or over  
4 Go back to step 1 This makes a total cycle time of 8h from step1 to step3
  Transtition time(ie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition): From salt spray to dry:within 30min
从盐雾到干燥:30min内
From dry to wet:within 150 min
从干到湿:150分钟内
From wet to salt spray:within 30min
从湿到盐雾:30分钟内
The effect of the salt spray will,in principle,be instaneous。
For details of drying-air flow,see 6.4
盐雾的效果在原则上是瞬时的。
有关干燥空气流量的详细信息,请参见6.4
 

C.3 Salt fog depsiton rate盐雾沉降率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
当盐雾在24小时内被收集时,盐雾的沉积速率应该是1ml/h2ml/h(见第10条)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for 30 cycles(240h),60cycles(240h),90cycles(720h) or 180cycles(1440h)
除非另有约定,重复测试周期30周期(240h)、60周期(240h)、90周期(720h)或180周期(1440h

Cycle B

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,将氯化钠溶解在水中,使溶液的浓度为(50±10g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle. 设置盐雾箱执行以下循环。
Step Time h Temp Condition notes
1 24 35±2 Salt fog  
2 8 40±2 100%RH Water condensing on test panels
3 16 23±2 50±20%RH  
4 8 40±2 100%RH Water condensing on test panels
5 16 23±2 50±20%RH  
6 8 40±2 100%RH Water condensing on test panels
7 16 23±2 50±20%RH  
8 8 40±2 100%RH Water condensing on test panels
9 16 23±2 50±20%RH  
10 48 23±2 50±20%RH  
11 Go back to step 1 This makes the total cycle time 7 days from step1 to step10.
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate盐雾沉降率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for 840 h
除非另有约定,重复测试周期为840小时。
 

Cycle C

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (0.31±0.01)g/l and (4.1±0.01)g/l respectively  .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,在水中溶解氯化钠,浓度分别为(0.31±0.01g/L和(4.1±0.01g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle. 设置来执行以下循环。
Step Time min Temp Condition notes
1 210 30±2 Salt fog  
2 210 40±2 Dry Drying-air purge(see 6.4)
3 1470 40±2 75±15%RH One method of achieving this conditon is to alternate the dry and humid cycles for suitable(short)time periods to keep the RH between the limits specified
4 102 30±2 Dry Drying-air purge(see 6.4)
5 210 30±2 Salt fog  
6 378 30±2 90% to 100%RH Water condensing on test panel
7 180 35±2 Dry Drying-air purge(see 6.4)
8 120 25±2 Dry  
9 Go back to step 1 This makes the total cycle time 48h from step1 to step8.
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate盐雾沉降率

The salt fog deposition rate shall be 2ml/h to 4ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
当盐雾在24小时内被收集时,盐雾的沉积速率应为2ml/h4ml/h(见第10)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for1000h
除非另有约定,重复测试周期为1000小时。

Cycle D

C.1 Salt fog test solution盐雾试验溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5条所述的方法制备喷雾溶液,将氯化钠溶解在水中,使溶液的浓度为(50±10g/L,溶液的pH值在67范围内。

C.2 Cycle

Set up the cabinet to perform the following cycle,设置执行如下下循环
Step Time h Temp Condition Notes
1 0.5 30±2 Salt spray  
2 1.5 30±2 Wet:(95±3%RH  
3 2 50±2 Hot dry  
4 2 30±2 Warm dry  
5 Go back to step 1 This makes a total cycle time of 6h from step1 to step4
  Transtition timeie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition): From salt spray to wetwithin 10min
从盐雾到潮湿:10min以内
From wet to hot drywithin 15 min
从湿到热干燥:15分钟内
From hot dry to salt warm drywithin 30min
从热干燥到盐温干燥:30min
From salt warm dry to salt sprayinstaneous
从盐温干到盐雾:瞬时
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate盐雾排放率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
当盐雾在24小时内被收集时,盐雾的沉积速率应该是1ml/h2ml/h(见第10条)

C 4 Duration持续时间

Unless otherwise agreedrepeat the test cycle for 28 cycles(168h)
除非另有约定,重复测试周期为28个周期(168h)。

 


符合德国DIN EN ISO11997-1测试标准的循环腐蚀复合盐雾箱
参考文章:
1、CETP 0000-L-467全球试验室加速循环腐蚀试验标准中文翻译版
2、浅析福特汽车CETP 0000-L-467测试标准的试验步骤及方法
3、简析通用汽车GMW 1487标准的试验流程及步骤

 
关于我们
扫一扫,关注我们最新消息扫一扫,关注我们最新消息
联系我们
0769-88061129

工作时间:周一至周五 9:00-18:00

联系人:钟经理

手机:13600292956

邮件:dgkedi@qq.com

地址:东莞市寮步镇泉塘工业区中星街3号

底部导航
东莞市科迪仪器有限公司成立于2000年,专业从事试验仪器设备的生产厂家,主要产品系列有智能触摸屏盐雾箱、复合式盐雾箱、二氧化硫试验箱、全自动盐水浸泡试验箱、电解测厚仪、涂层测厚仪、恒温试验箱 、高低温试验箱、冷热冲击试验箱、紫外光辐射试验箱、氙灯老化试验箱等检测仪器设备。科迪仪器拥有雄厚的技术实力和全新的经营管理模式,有一支优良的技术人才团队,致力于为客户提供完善的实验室解决方案!从实验室的建立到试验设备的选择,均会有专业人员予以全程指导与建议,让客户足不出户便能享受到专业团队的贴心服务,以合理实惠的价格协助采购到性价比最高的仪器设备,我们相信客户需要的产品不是越贵越好,而是适合自己的才是最好的!